Attenuation at 1310 nm | Max. 0.36 dB/km |
---|---|
Attenuation at 1550 nm | Max. 0.22 dB/km |
Aerial installation.
Single outer sheath, Multi loose tube, Water blocking swellable material.
Outer Sheath Material | MDPE & HDPE black according to ASTM D 1248 type II class C |
Outer Sheath Thickness | 1.6 mm ± 0.1 |
Loose Buffer Tube | PBT (Polybutylene terephthalate) |
Filling Compound in Loose Tube | Thixotropic Jelly Compound |
Tube Outer Diameter | 2.30 mm ± 0.07 |
Tube Inner Diameter | 1.40 mm ± 0.07 |
Central Strength Member | FRP |
FRP Diameter | 2.50 mm ± 0.07 |
Core Wrapping Tape | Water swellable tape |
Auxiliary Strength Member | Aramid Yarn |
Steel Rope Diameter | 7 × 0.9 mm |
Ripcord | Yes, under outer sheath |
Cable Outer Diameter | Depends on number of fibers and loose tubes, range from 12.0 to 13.0 mm ± 0.07 |
Web Dimensions | 2.5 × 2.5 mm |
No. | Cable Test | Standard | Requirements |
---|---|---|---|
1 | Tensile Strength (installation) | IEC 60794-1 E1 | Min 4.000N Attenuation Change (Max 0.05 dB) |
2 | Tensile Strength (Operation) | IEC 60794-1 E1 | Min 2.500N Attenuation Change (Max 0.05 dB) |
3 | Cable Bend 20×D | IEC 60794-1-E11 | Attenuation Change (Max 0.05 dB) No Damage or breakage of the cable |
4 | Impact Test: 1 meter 50 N | IEC 60794-1-E4 | Attenuation Change (Max 0.05 dB) |
5 | Crush Strength: 200 N/cm | IEC 60794-1-E3 | Attenuation Change (Max 0.05 dB) |
6 | Torsion Test: 2 meter 10 kg ±180⁰ 10 cycles (20 times) | IEC 60794-1-E7 | Attenuation Change (Max 0.05 dB) |
7 | Flexing Test: 20×D, 30 cycles/min | IEC 60794-1-E8 | Attenuation Change (Max 0.05 dB) No Damage or breakage of the cable |
8 | Kink Test: 3 meter, formed into loop, Min 20×D | IEC 60794-1-E10 | Attenuation Change (Max 0.05 dB) |
9 | Repeated Bending Test: 10 cycles, 10 kg load, L > 1.5 meter, 20×D | IEC 60794-1-E6 | Attenuation Change (Max 0.1 dB) |
10 | Temperature Cycling (-40⁰C to +80⁰C) | IEC 60794-1-F1 | Transition from 20⁰C to -40⁰C: 4 hours Duration -40⁰C: 36 hours Transition from -40⁰C to 80⁰C: 4 hours Duration +80⁰C: 36 hours Duration of each cycle: 36 hours Number of cycles: 1 Attenuation Change (Max 0.5 dB) |
11 | Water penetration: 3 meter, 24 hours | IEC 60794-1-E5 | No Leakage at the end of the cable |
12 | Filing & Flooding compound flow | IEC 60794-1-E14 | No flow |
PAMIX A-MLT-S02 Aerial Fiber Cable Steel wire <Product Number> <Number of fiber cores> SM 9/125 G.652 d <Lot No.> <meter count>
* Cable marking can be customized to meet customer needs.
25 years performance warranty, refer to PAMIX Worldwide warranty terms.
Description | Art. Number |
---|---|
PAMIX A-MLT-S02 Aerial Multi Loose Tube 6×4 cores, SM G.652 d, single jacket, Steel Wire | 1012991 |
PAMIX A-MLT-S02 Aerial Multi Loose Tube 3×12 cores, SM G.652 d, single jacket, Steel Wire | 1012992 |
PAMIX A-MLT-S02 Aerial Multi Loose Tube 4×12 cores, SM G.652 d, single jacket, Steel Wire | 1012993 |
PAMIX A-MLT-S02 Aerial Multi Loose Tube 6×12 cores, SM G.652 d, single jacket, Steel Wire | 1012994 |
PAMIX A-MLT-S02 Aerial Multi Loose Tube 8×12 cores, SM G.652 d, single jacket, Steel Wire | 1012995 |
* Other cable designs can be customized based on customer request.