PAMIX MLT-S10 Outdoor Fiber Cable

SM 9/125 (G.652 d)

Attenuation at 1310 nm Max. 0.35 dB/km
Attenuation at 1550 nm Max. 0.21 dB/km

 

Application

Suitable for pulling in or blowing through ducts, laying on cable trays or direct buried. High protection against rodent.
 

General Construction

Multi loose tube, Corrugated steel tape, Glass yarn, Water blocking swellable material, Single outer sheath
 

Cable Design

Outer Sheath Material MDPE & HDPE black according to ASTM D 1248 type II class C (Protection against sun and UV)
Outer Sheath Thickness 1.6 mm ± 0.1
Loose Buffer Tube PBT (Polybutylene terephthatlate)
Tube Diameter 2.25 ±0.07 mm
Tube Inner Diameter 1.40 ±0.07 mm
Filling Compound in Loose Tube Thixotropic Jelly Compound
Central Strength Member FRP
Core Wrapping Tape Water swellable tape
Water Blocking Material Water Swellable Material
Auxiliary Strength Member Glass Yarn
Armoring Corrugated Steel tape 0.155 mm ± 0.015
FRP Diameter 2.40 ±0.07 mm
Ripcord Yes, under outer sheath
Cable Outer Diameter 12mm to 16mm depending on number of fibers and tubes

 

Performance and Standards

No. Cable Test Standard Requirements
1 Tensile Strength (installation) IEC 60794-1 E1 Min 2.700N Attenuation Change (Max 0,05 dB)
2 Tensile Strength (Operation) IEC 60794-1 E1 Min 2.000N Attenuation Change (Max 0,05 dB)
3 Cable Bend 20xD IEC 60794-1-E11 Attenuation Change (Max 0,1 dB) No Damage or breakage of the cable
4 Impact Test: 1 meter 10 N IEC 60794-1-E4 Attenuation Change (Max 0,05 dB)
5 Crush Strength: 200 N/cm IEC 60794-1-E3 Attenuation Change (Max 0,05 dB)
6 Torsion Test: 2 meter 10 kg ±180⁰ 10 cycles(20 times) IEC 60794-1-E7 Attenuation Change (Max 0,05 dB)
7 Flexing Test: 20xD, 30 cycles/min IEC 60794-1-E8 Attenuation Change (Max 0,05 dB) No Damage or breakage of the cable
8 Kink Test: 3 meter, formed into loop, Min 20xD IEC 60794-1-E10 Attenuation Change (Max 0,05 dB)
9 Repeated Bending Test: 10 cycle, 10 kg load, L>1.5 meter, 20xD IEC 60794-1-E6 Attenuation Change (Max 0,1 dB)
10 Temperature Cycling (-40⁰C to +80⁰C) IEC 60794-1-F1 Attenuation Change (Max 0,05 dB)
11 Water penetration: 3 meter, 24 hour IEC 60794-1-E5 No Leakage at the end of the cable
12 Filing & Flooding compound flow IEC 60794-1-E14 No flow

 

Cable Marking

PAMIX MLT-S10 Outdoor Fiber Cable <Product Number> <Number of fiber cores> SM 9/125 G.652 d <Lot No.> <meter count>

* Cable marking can be customized to meet customer needs.
 

Warranty

25 years performance warranty, refer to PAMIX Worldwide warranty terms.
 

Ordering Information

Description Art. Number
PAMIX MLT-S10 Outdoor Fiber cable 1×12 cores, SM G.652 d, single jacket. 1012667
PAMIX MLT-S10 Outdoor Fiber cable 2×6 cores, SM G.652 d, single jacket. 1012668
PAMIX MLT-S10 Outdoor Fiber cable 1X24 cores, SM G.652 d, single jacket. 1012669
PAMIX MLT-S10 Outdoor Fiber cable 2×12 cores, SM G.652 d, single jacket. 1012670
PAMIX MLT-S10 Outdoor Fiber cable 4×6 cores, SM G.652 d, single jacket. 1012671
PAMIX MLT-S10 Outdoor Fiber cable 3×12 cores, SM G.652 d, single jacket. 1012672
PAMIX MLT-S10 Outdoor Fiber cable 4×12 cores, SM G.652 d, single jacket. 1012673
PAMIX MLT-S10 Outdoor Fiber cable 6×12 cores, SM G.652 d, single jacket. 1012674
PAMIX MLT-S10 Outdoor Fiber cable 8×12 cores, SM G.652 d, single jacket 1012675
PAMIX MLT-S10 Outdoor Fiber cable 12×12 cores, SM G.652 d, single jacket. 1012676

* Other cable designs can be customized based on customer request.

 

Ask a Question