Attenuation at 1310 nm | Max. 0.35 dB/km |
---|---|
Attenuation at 1550 nm | Max. 0.21 dB/km |
Suitable for pulling in or blowing through ducts, laying on cable trays or direct buried. High protection against rodent.
Multi loose tube, Corrugated steel tape, Glass yarn, Water blocking swellable material, Single outer sheath
Outer Sheath Material | MDPE & HDPE black according to ASTM D 1248 type II class C (Protection against sun and UV) |
Outer Sheath Thickness | 1.6 mm ± 0.1 |
Loose Buffer Tube | PBT (Polybutylene terephthatlate) |
Tube Diameter | 2.25 ±0.07 mm |
Tube Inner Diameter | 1.40 ±0.07 mm |
Filling Compound in Loose Tube | Thixotropic Jelly Compound |
Central Strength Member | FRP |
Core Wrapping Tape | Water swellable tape |
Water Blocking Material | Water Swellable Material |
Auxiliary Strength Member | Glass Yarn |
Armoring | Corrugated Steel tape 0.155 mm ± 0.015 |
FRP Diameter | 2.40 ±0.07 mm |
Ripcord | Yes, under outer sheath |
Cable Outer Diameter | 12mm to 16mm depending on number of fibers and tubes |
No. | Cable Test | Standard | Requirements |
---|---|---|---|
1 | Tensile Strength (installation) | IEC 60794-1 E1 | Min 2.700N Attenuation Change (Max 0,05 dB) |
2 | Tensile Strength (Operation) | IEC 60794-1 E1 | Min 2.000N Attenuation Change (Max 0,05 dB) |
3 | Cable Bend 20xD | IEC 60794-1-E11 | Attenuation Change (Max 0,1 dB) No Damage or breakage of the cable |
4 | Impact Test: 1 meter 10 N | IEC 60794-1-E4 | Attenuation Change (Max 0,05 dB) |
5 | Crush Strength: 200 N/cm | IEC 60794-1-E3 | Attenuation Change (Max 0,05 dB) |
6 | Torsion Test: 2 meter 10 kg ±180⁰ 10 cycles(20 times) | IEC 60794-1-E7 | Attenuation Change (Max 0,05 dB) |
7 | Flexing Test: 20xD, 30 cycles/min | IEC 60794-1-E8 | Attenuation Change (Max 0,05 dB) No Damage or breakage of the cable |
8 | Kink Test: 3 meter, formed into loop, Min 20xD | IEC 60794-1-E10 | Attenuation Change (Max 0,05 dB) |
9 | Repeated Bending Test: 10 cycle, 10 kg load, L>1.5 meter, 20xD | IEC 60794-1-E6 | Attenuation Change (Max 0,1 dB) |
10 | Temperature Cycling (-40⁰C to +80⁰C) | IEC 60794-1-F1 | Attenuation Change (Max 0,05 dB) |
11 | Water penetration: 3 meter, 24 hour | IEC 60794-1-E5 | No Leakage at the end of the cable |
12 | Filing & Flooding compound flow | IEC 60794-1-E14 | No flow |
PAMIX MLT-S10 Outdoor Fiber Cable <Product Number> <Number of fiber cores> SM 9/125 G.652 d <Lot No.> <meter count>
* Cable marking can be customized to meet customer needs.
25 years performance warranty, refer to PAMIX Worldwide warranty terms.
Description | Art. Number |
---|---|
PAMIX MLT-S10 Outdoor Fiber cable 1×12 cores, SM G.652 d, single jacket. | 1012667 |
PAMIX MLT-S10 Outdoor Fiber cable 2×6 cores, SM G.652 d, single jacket. | 1012668 |
PAMIX MLT-S10 Outdoor Fiber cable 1X24 cores, SM G.652 d, single jacket. | 1012669 |
PAMIX MLT-S10 Outdoor Fiber cable 2×12 cores, SM G.652 d, single jacket. | 1012670 |
PAMIX MLT-S10 Outdoor Fiber cable 4×6 cores, SM G.652 d, single jacket. | 1012671 |
PAMIX MLT-S10 Outdoor Fiber cable 3×12 cores, SM G.652 d, single jacket. | 1012672 |
PAMIX MLT-S10 Outdoor Fiber cable 4×12 cores, SM G.652 d, single jacket. | 1012673 |
PAMIX MLT-S10 Outdoor Fiber cable 6×12 cores, SM G.652 d, single jacket. | 1012674 |
PAMIX MLT-S10 Outdoor Fiber cable 8×12 cores, SM G.652 d, single jacket | 1012675 |